Power Infrastructure Built for AI Data Centers
Behind-the-meter battery storage, containerized substations, and modular UPS systems for hyperscale campuses. Pair storage with turbines and generators for remote, bring-your-own-power projects, or integrate with existing utility-connected infrastructure.
Enterprise-Grade Product Lines
UPS, BESS & Substations · Lead Times
12–16 weeks production lead time, plus 4–8 weeks for shipping.
Expediting options are available. Contact us to discuss your project schedule.
Behind-the-Meter Power Solutions
Bring your own power to remote data centers. Pair BESS and substations with turbines or generators for a site-engineered solution without a utility connection. Explore a 40 MW / 80 MWh storage reference.
View productContainerized Substations
5 MW / 34.5 kV substations in 40-foot containers, each sized to connect two 2.5 MW BESS units. Project-specific electrical interfaces and interconnection scope.
View productModular UPS Systems
Six GM100 modules per 600 kVA rack. Scale to six or more racks for 3.2 MW+ configured systems, subject to approved engineering and redundancy. Single racks from $375,000; multi-rack systems quoted per project.
View productHigh-Cycling UPS Systems
High cycling durability architectures designed for extended ride-through, minimizing chemical battery dependence and reducing maintenance.
View productData Center BESS
LFP battery energy storage for AI data center peak shaving and grid independence. 1 MWh to 4 MWh+. Starting at $380,000.
View productIntegrated Power Blocks
Switchboards, transformers, panelboards, cable bus, and controls integrated into single skids.
E-Houses / Powerhouses
Factory-built electrical rooms maintaining NEC clearances. Transportable integrated systems with factory QA/QC.
Cable Tray Systems
Wire basket, perforated, and ladder tray for data center cable management. 4″ depth × 6″–36″ widths. Standard from $8/lf, fully landed anywhere in the USA.
View productBuildingFab Power Architecture
Inside a BuildingFab Power Block
Medium Voltage Transformers
Step-down from utility MV to distribution LV. Factory-wound, tested, and integrated with protection systems before leaving the factory floor.
Low Voltage Switchboards
Main distribution boards factory assembled with breakers, metering, and controls. Tested under load prior to shipment.
Distribution Panelboards
Branch circuit distribution factory wired and tested. Labeled, documented, and ready for connection on arrival.
UPS Systems
Modular lithium-ion UPS from 500kW to multi-MW. Pre-integrated with battery strings and controls.
Battery Energy Storage
Grid-scale and data center BESS with integrated BMS, thermal management, and fire suppression interfaces.
Cable Bus & Busway
High-ampacity distribution integrated and tested within the power block structure.
Integrated Controls & Monitoring
SCADA, metering, protection relays, and communications pre-configured and tested as a system.
E-House Structure
Steel-framed electrical rooms with HVAC, lighting, cable management, and NEC-compliant working clearances built in.
Why AI Data Centers Need New Power Architectures
AI training and inference workloads do not look like traditional cloud workloads. GPU clusters create massive, volatile power swings that stress conventional electrical infrastructure and grid connections.
- Dramatic power density growth per rack
- Severe load spikes during training runs
- Grid constraints forcing on-site peak shaving
- Extreme speed-to-market pressures
Traditional vs AI Load Volatility (kW)
Flexible OEM Integration
We do not lock you into a single manufacturer—we provide the engineering and integration wrapper that guarantees the system works perfectly together.
Global OEM Sourcing
BuildingFab sources components from qualified OEM partners across multiple regions. This eliminates single-source dependency and protects customers from supply chain disruptions.
Engineering Integration
Components from multiple OEMs are engineered into a unified system. Interface design, protection coordination, controls integration, and system-level FAT are performed centrally.
Unified Warranty
Instead of managing separate warranties for switchgear, UPS, and batteries across multiple vendors, BuildingFab provides a single point of responsibility for the integrated system.
Factory-Built vs Traditional Field Construction
| Criteria | Traditional Field Construction | BuildingFab Factory Integration |
|---|---|---|
| Integration Responsibility | Multiple vendors, site coordinated, highly fractured. | Single integration platform, assembled before shipping. |
| Deployment Schedule | Sequential, weather dependent, long commissioning. | Parallel manufacturing, accelerated delivery. |
| Labor Exposure | High local field labor requirements and costs. | Shifted to controlled factory environment. |
| Quality Assurance | Field tested under varying site conditions. | Rigorous factory acceptance testing (FAT) prior to deployment. |