Data Center Infrastructure

GM100 Modular UPS. 600 kVA to 3.2 MW+.

Start with six GM100 modules in a 600 kVA rack. Scale to six or more coordinated racks for 3.2 MW+ systems, with online double-conversion, hot-swap serviceability and project-specific redundancy for data center critical power.

600 kVA from $375,0006+ racks · 3.2 MW+ configured systemsHot-swap GM100 modules

UPS, BESS & Substations · Lead Times

12–16 weeks production lead time, plus 4–8 weeks for shipping.

Expediting options are available. Contact us to discuss your project schedule.

Available Models

1600 kVA

1600 kVA Rack with 16×GM100

Starting at$800,000
Voltage480V, 60Hz (400–480V)

600 kVA

600 kVA Rack with 6×GM100

Starting at$375,000
Voltage480V, 60Hz (400–480V)
Online double-conversion topology
Hot-swap GM100 power modules
Three-breaker configuration

Module → rack → multi-rack system

One rack today. Multi-megawatt capacity as you grow.

6 GM100 modules

Populate one 600 kVA rack with six 100 kVA modules. This is the modular building block.

6+ coordinated racks

Combine six or more 600 kVA racks through an approved parallel architecture, with coordinated controls, bypass and electrical distribution.

3.2 MW+ systems

Configure active-power capacity around your critical load, operating power factor, redundancy reserve and site conditions.

Six 600 kVA racks total 3,600 kVA of nameplate apparent power, not an unconditional 3.6 MW of usable output. The 3.2 MW+ configuration target is subject to approved engineering, power factor, redundancy and derating. Rack count, battery runtime and system-level pricing are confirmed per project; single-rack starting prices below are not multi-rack package prices.

Discuss a Multi-Rack Configuration

UPS Models

Rack Options for Your UPS System

Single-Rack Option
1600 kVA

1600 kVA Modular UPS

1600 kVA Rack with 16×GM100

Starting at $800,000

Full-rack modular UPS designed for hyperscale and large enterprise data center deployments. Sixteen GM100 power modules deliver 1600 kVA of clean, conditioned power with N+1 or N+2 module-level redundancy — no single module failure takes down the system.

Voltage

480V, 60Hz (400–480V)

Modules

16×GM100

Topology

Online double-conversion

Breakers

3 (Input / Output / MBB)

Included Breakers

  • Input breaker
  • Output breaker
  • Maintenance bypass breaker
  • 16 hot-swappable GM100 power modules
  • Input, output, and maintenance bypass breakers
  • Online double-conversion topology
  • Module-level N+1 / N+2 redundancy
  • Hot-swap modules — zero downtime maintenance
  • Wide input range: 400–480V, 60Hz
  • SNMP / RS-232 / dry contact monitoring
Scalable Building Block
600 kVA

600 kVA Modular UPS

600 kVA Rack with 6×GM100

Starting at $375,000

Six GM100 power modules form a 600 kVA rack. Start with one rack and build a coordinated array of six or more 600 kVA racks for configured systems of 3.2 MW+. Final usable output depends on power factor, redundancy reserve, derating and the approved design.

Voltage

480V, 60Hz (400–480V)

Modules

6×GM100

Topology

Online double-conversion

Breakers

3 (Input / Output / MBB)

Included Breakers

  • Input breaker
  • Output breaker
  • Maintenance bypass breaker
  • 6 hot-swappable GM100 power modules
  • 600 kVA racks scale to 6+ rack arrays / 3.2 MW+ systems
  • Input, output, and maintenance bypass breakers
  • Online double-conversion topology
  • Module-level N+1 redundancy
  • Hot-swap modules — zero downtime maintenance
  • Wide input range: 400–480V, 60Hz
  • SNMP / RS-232 / dry contact monitoring

Custom capacity configurations available. Contact BuildingFab for project-specific sizing and multi-unit deployments.

Why BuildingFab Modular UPS

Built for Critical Power Continuity

Online Double-Conversion

Both UPS models use true online double-conversion topology — all load power passes through the inverter continuously, ensuring zero transfer time and full isolation from utility disturbances.

Hot-Swap Modules

GM100 power modules can be swapped under live load without a maintenance window. N+1 and N+2 configurations mean a module failure never interrupts the protected load.

Three-Breaker Configuration

Every rack includes a dedicated input breaker, output breaker, and a true maintenance bypass breaker — enabling full UPS isolation for servicing without dropping the critical load.

Wide Input Voltage

Accepts input voltage from 400V to 480V at 60Hz, accommodating variance in utility supply and facility switchgear without battery stress or derating.

Rack-Integrated Design

Both capacities are delivered as complete, integrated rack assemblies. Modules, breakers, and monitoring are factory-installed and tested — ready for commissioning on arrival.

600 kVA Racks to 3.2 MW+

Populate each 600 kVA rack with six GM100 modules, then scale the system with six or more racks. Coordinated multi-rack configurations support 3.2 MW+; usable critical-load capacity depends on the approved electrical and redundancy design.

Standards & Certifications

UL Listed
CE Marked
IEC 62040
ISO 9001
SNMP Ready
Double Conversion

Get Pricing

Request a UPS Quote